About inverter harmonic control

The importance of harmonic control Xiangyang Yuanchuang Electric has been committed to the development of industrial control electrical industry, "survive by quality, create brand by reputation" to adhere to the electrical products with good quality and reputation. The filter compensation device is also with Tsinghua University and Wuhan. University cooperation has achieved significant benefits.


This chapter mainly analyzes several methods of governance of harmonics.

With the development of power electronics technology, inverters are increasingly used in many fields such as power electronics systems and industries. The high-order harmonics generated by inverters are also increasingly harmful to the public power grid.

These include:

1) Harmonics cause additional harmonic losses in components in the power grid, reducing the efficiency of power generation, transmission, and electrical equipment. A large number of 3 harmonics flowing through the neutral line can overheat or even cause a fire.

2) Harmonics affect the normal operation of various electrical equipment, causing mechanical vibration, noise and overheating of the motor, causing severe overheating of the transformer, causing overheating of capacitors, cables and other equipment, causing insulation aging, shortening life and even damage;

3) Harmonics will cause local parallel resonance and series resonance in the power grid, which will amplify the harmonics and cause serious accidents;

4) Harmonics will cause interference to adjacent communication systems, lighter noise will be generated, and communication quality will be reduced, resulting in loss of information and failure of the communication system to work properly;

5) Harmonics can cause relay protection and malfunction of the automatic device, and make the measurement of the electrical measuring instrument inaccurate.

Since the harmonic voltage and harmonic current in the utility grid cause great harm to the electrical equipment and the power grid itself, many countries in the world have issued national standards for limiting the harmonics of the power grid, and the authority has established regulations for limiting harmonics. The harmonic standards set by countries all over the world are mostly close. In 1993, China's Technical Supervision Bureau issued the National Standard (gb/t14549-93) "Power Quality Harmony of Utility Grid", which was implemented from March 1, 1994.

The frequency converter is one of the most widely used equipment in the field of industrial adjustment transmission. The frequency converter is a device that converts the power frequency (50hz) into an AC power source of various frequencies to realize the variable speed operation of the motor. The control circuit completes the control of the main circuit, the rectifier circuit converts the alternating current into direct current, and the direct current circuit smoothes the output of the rectifier circuit, and the inverter circuit inverts the direct current into alternating current. Due to the switching characteristics of the inverter inverter circuit, a typical non-linear load is formed for the common power supply. Therefore, the power electronic device represented by the frequency converter is one of the most important harmonic sources in the public power grid.

Harmonic refers to each component of the quadratic series decomposition of periodic non-orthogonal alternating current quantities that is greater than an integer multiple of the fundamental frequency, and is also commonly referred to as higher harmonics. Since there are various sources of harmonics in the power system (harmonic sources are electrical devices that inject harmonic currents into the utility grid or generate harmonic voltages in the utility grid), especially devices such as converters. The mechanism for generating harmonics on the input side of the inverter is that any rectifier circuit on the power supply side generates harmonics due to its nonlinearity. The mechanism for generating harmonics on the output side of the inverter is: In the inverter circuit, for a voltage type circuit, the output voltage is a rectangular wave. For current-mode circuits, the output current is a rectangular wave. Rectangular waves contain more harmonics, which have an adverse effect on the load. Therefore, even if the voltage of the power supply in the power system is a sine wave, there will always be harmonic current or voltage in the power grid due to the existence of nonlinear components. Therefore, the existence of grid harmonics mainly lies in the existence of various nonlinear components in the power system.
The active filter compensation device is the most ideal harmonic control. If you are interested, please consult my company.
Http://news.chinawj.com.cn Editor: (Hardware Business Network Information Center) http://news.chinawj.com.cn


We are involved in offering high-quality Cnc Plasma Cutting Machine to our valuable customers. These products are made from high-quality components.Our company are prominent manufacturers and exporters of high-quality Auto Duct Forming and Cut to Length Machines. Offered products range consists of Auto Duct Forming Machine, Cut to Length Machine and Roll Former Machine. All offered products are manufactured under the direction of experts using quality tested material and latest technology as per industry norms. Sturdy designs, fine finish, high strength, long service life and damage resistance are features of our offered range of products.

Gantry Double Plasma Cnc Cutting Machine is a stereotyped product carefully developed by our company. It has high processing efficiency and is 2.2 times of single gun cutting. It is a numerical control equipment for metal sheet blanking. It not only has an appearance atmosphere, but also has stable operation, high work efficiency and long service life. It can realize cutting of any metal material according to any pattern. It is widely used in the cutting of sheet metal in various mechanical manufacture industry.

Type

BLDS-3060

BLDS-4080

BLDS-5080

BLDS-60100

BLDS-80100

Input power

AC380V/50Hz; AC220V/50Hz

Track gauge(mm)

3000

4035

5000

6000

8000

Effective cutting width(mm)

2300

3300

4300

5300

7300

Machine width(mm)

3500

4300

5500

6500

8500

Track length(mm)

6000

8000

8000

10000

10000

Number of cutting torch(set)

2

2

2

2

2

Lift(mm)

200

Cutting thickness(mm)

1~30(According to the power supply size)

Cutting speed (mm/min)

450~5000

Idle speed(mm/min)

0~8000

Drive mode

Bilateral drive

System

Shanghai Jiaoda or Beijing Starfire

Operating accurancy

±0.5mm



Gantry Double Plasma CNC Cutting Machine